《Table 2–Comparison of maximum voltage, power density and internal resistance with different pH and

《Table 2–Comparison of maximum voltage, power density and internal resistance with different pH and   提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《Nitrite pre-treatment of dewatered sludge for microbial fuel cell application》


  1. 获取 高清版本忘记账户?点击这里登录
  1. 下载图表忘记账户?点击这里登录

Polarization analyses were done on the MFCs operated with100 mg-N/L of nitrite addition and different pH(shown in Appendix A).The internal resistance of MFC for pH 5,6,7,8,and 9 was around 2080,1240,280,240,and 200Ω,respectively as shown in Table 2.The internal resistance of the MFC was lowest at pH 9(alkaline condition).The high internal resistance under acidic condition could be due to the inhibition effect of the FNA and unfavorable pH effect on the population of electrogenic bacteria at the anode.Under alkaline condition,the higher substrate availability compared to that under neutral condition,and lower FNA inhibition,contributed to the lower internal resistance within the MFC and thus resulted in higher power density for the MFC.This study showed that the alkaline condition combined with nitrite pre-treatment of sludge is a viable way to increase the power generation of a MFC.