《Table 4–“Tableting properties”of formulations with different amounts of lubricant, evaluated using
本系列图表出处文件名:随高清版一同展现
《Formulation design of granules prepared by wet granulation method using a multi-functional single-punch tablet press to avoid tableting failures》
We have previously shown that it is advisable to design formulations to optimize both“Compactability”and“Manufacturability”,but the results of Samples 1,6,and 7 showed high ejection stress(≥5 MPa),and the points were plotted in range(III),indicating poor“Manufacturability”.Insufficient Mg St causes tableting failures such as sticking and binding[16].To improve“Manufacturability”,we added different amounts of MgSt to Sample 1-based formulations.Each tablet contained0.6 mg Mg St in Sample 8,1.2 mg Mg St in Sample 1,2.4 mg Mg St in Sample 9,and 3.2 mg Mg St in Sample 10.The ejection stress decreased as the amount of lubricant increased(Table 4;Fig.4).That of Sample 8 was extremely high,and the sides of the tablets were deeply damaged during ejection.For this reason,TFS of Sample 8 was low.Samples 9(2.4 mg Mg St)and 10(3.6 mg Mg St)were plotted in range(I),indicating good“Compactability”and“Manufacturability”(Table 4;Fig.4).
图表编号 | XD00593500 严禁用于非法目的 |
---|---|
绘制时间 | 2018.03.01 |
作者 | Takashi Osamura、Yoshiko Takeuchi、Risako Onodera、Masahiro Kitamura、Yoshiteru Takahashi、Kohei Tahara、Hirofumi Takeuchi |
绘制单位 | Laboratory of Pharmaceutical Engineering, Gifu Pharmaceutical University、Pharmaceutical Technology Department, Sawai Pharmaceutical Co.Ltd、Laboratory of Pharmaceutical Engineering, Gifu Pharmaceutical University、Laboratory of Pharmaceutical Engineering, G |
更多格式 | 高清、无水印(增值服务) |