《Table 5.Equivalent-circuit parameters for the 316L SS as a function of the cold-working level》
提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《"Effect of cold rolling on the microstructural, magnetic, mechanical, and corrosion properties of AISI 316L austenitic stainless steel"》
Fig.7 shows the potentiodynamic polarization plots for the annealed and as-cold-rolled samples in the Na Cl(1mol/L)+H2SO4(0.5 mol/L)solution.To simplify this discussion,all electrochemical corrosion parameters obtained from the polarization plots and represented in Table 3 are divided into three categories:uniform corrosion(on the basis of Icorr,CI,CPR,and Rcorr parameters),passive-layer properties(on the basis of Eb-Epp and Ip/Ic parameters),and sensitivity to pitting corrosion(on the basis of Eb,pit-Erp and Irp parameters),as follows:
图表编号 | XD002871200 严禁用于非法目的 |
---|---|
绘制时间 | 2018.06.01 |
作者 | S.Tanhaei、Kh.Gheisari、S.R.Alavi Zaree |
绘制单位 | Department of Materials Science and Engineering, Faculty of Engineering, Shahid Chamran University of Ahvaz、Department of Materials Science and Engineering, Faculty of Engineering, Shahid Chamran University of Ahvaz、Steel Research Center, Faculty of Engin |