《Table 2 Electrochemical corrosion parameters of Al-Cu-Li alloy weldment in 3.5%Na Cl solution》

《Table 2 Electrochemical corrosion parameters of Al-Cu-Li alloy weldment in 3.5%Na Cl solution》   提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《时效处理对铝锂合金电子束焊接头耐蚀性能的影响(英文)》


  1. 获取 高清版本忘记账户?点击这里登录
  1. 下载图表忘记账户?点击这里登录
Note:self-corrosion potential,Ecorr;self-corrosion current,Icorr;pitting corrosion potential,Epit;passivation interval,(Epit-Ecorr)

The EXCO is closely related to IGC;it usually develops from pitting corrosion to IGC,and rapidly expands along grain boundary.When the grain boundary is corroded to form corrosion path,the wedge tension will be produced to ambient grains,and it causes tearing of non-corroded parts;the exfoliation occurs in a large area,and even makes alloy break up[4].The morphologies of Al-Cu-Li alloy joint immersed in EXCO solution before and after PWHT are shown in Fig.4.The course of EXCO development of Al-Cu-Li alloy joint is given in Table 1.