whereνis the kinematic viscosity of the fluid[16].As the geometry of groove and the characteristics of coolant remain constant,the Deandνhave no change.So the Reynolds number Reis in direct proportion to the water flow rate.Finally,we take water flow rate 1 100 L/min namely the water velocity 2.3 m/s for each groove as the optimal value within the experimental tolerance limit[15,17].In this case,the alpha is 6 000 W/m2·℃and the Reis 20062 which means the coolant DI water is turbulent flow so the capability of transferring heat is in the highest level among three kinds of liquid conditions,laminar,transient and turbulent.The temperature distribution of collector cooling system is listed in Table 5.The maximum temperature of collector surface and outer water are lower than safety limit 300℃and 70℃,respectively.