《Table 1 Configuration of power supply and distribution system》

《Table 1 Configuration of power supply and distribution system》   提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《嫦娥四号中继星供配电系统设计与应用(英文)》


  1. 获取 高清版本忘记账户?点击这里登录
  1. 下载图表忘记账户?点击这里登录

The schematic diagram of PSDS of Chang’e 4 relay satellite is shown in Figure 1.The 28 V-half-regulated power bus topology was adopted to reduce the weight and volume of PCDU effectively.The power from SA is regulated by the PCDU via S4R circuits in the sunlight zone so that a steady bus voltage is established and the battery could be charged[2].This topology which is much simpler than an all-regulated one would let the battery supply all the devices on this satellite directly through the discharging switches at a very high efficiency without BDRs(Battery Discharge Regulator).The configuration of PSDS is listed in Table 1.