《Table 2 Heat transfer power per meter of heat transfer pipes》
提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《Research on single hole heat transfer power of ground source heat pump system》
According to the monitoring data of the recycling capacity of GSHP units together with temperature of supply and return main,the total heat supply volume of the heat exchange system during a heating period can be calculated.The results show that the heat transferred from gneiss to GSHP system totals 1 235.7×106 k J.Daytime heat supply fluctuates between 154 kw and 201 kw in response to changes of air temperature and operation time of heat pumps.Average output is180.8 kw,which equals to transfer power of heat exchange pipes per meter varying from 11.6 w to15.1 w,with an average power of 13.59 w(Table 2).
图表编号 | XD0016466900 严禁用于非法目的 |
---|---|
绘制时间 | 2018.03.01 |
作者 | ZHAO Fang-hua |
绘制单位 | The Third Party of Hydrogeology and Engineering Geology, Hebei Provincial Bureau of Geology and Mineral Investigation |