《Table 3–Experimental procedures for the respirogram determination.》

《Table 3–Experimental procedures for the respirogram determination.》   提示:宽带有限、当前游客访问压缩模式
本系列图表出处文件名:随高清版一同展现
《Tuning of activated sludge in winter based on respirogram profiles under standard and site temperatures》


  1. 获取 高清版本忘记账户?点击这里登录
  1. 下载图表忘记账户?点击这里登录

Respirogram space measurement,which includes several coordinates representing different activities(oxygen uptake rates,OUR)under different substrate conditions,has been described in previous research(Li et al.,2018b).The respiration rates were measured offline using an automatic respirogram apparatus(WBM400,Xi'an Lvbiao Water Environmental Technology Co.,China)composed of a 1.2 L glass container,an aerator(compressor and fine bubble aerator stone),a DO probe(VisiFerm DO 120,Hamilton,Switzerland),a pH probe(Polilyte Plus Arc 120,Hamilton,Switzerland)and a programmable logic controller(PLC).Online monitoring of pH and temperature variations in the built-in vessel of the apparatus was performed,meanwhile the pH was controlled at 7.5–8.5 by adding HCl or NaOH,and the temperature was maintained at the target values of site(T°C)and standard(20°C)temperatures using the same bath(BILON-W-503B Xi'an Bilon Experimental Equipment Co.,China).The detailed experimental protocols for the respirogram determination are listed in Table 3.