《Short and long-term outcomes of angle supported phakic intraocular lens implantation in high myopic eyes》


  1. 获取 高清版本忘记账户?点击这里登录
  1. 下载图表忘记账户?点击这里登录
ECD:Endothelial cell density;CDVA:Corrected distance visual acuity;p IOL:Phakic intraocular lens.P<0.001 both for difference of mean of ECD and CDVA.

We studied 36 eyes of 21 patients.The median age was 27y(20-37y).The mean central corneal thickness(CCT)was552±36μm.The median spherical equivalent was-10.5 D(25%quartile-11 D).The mean K1 and K2 were 42.2±1.3 and44.2±1.0 D respectively.The ECD at the different visits are presented in Table 1.There was acute loss of ECD in the 6mo following surgery and steady loss of ECD over the remaining period.An ECD loss of 33%is likely to occur 10y after angle supported p IOL implantation.The CDVA preoperatively and postoperatively is presented in Table 1.